{"product_id":"crst-r1-10s-ms3-1u-metered-switched-rack-pdu","title":"CRST 1U 10-Outlet Metered \u0026 Front-Switched Rack Mount Surge PDU (R1-10S-MS3)","description":"\u003cdiv class=\"crst-pdp-content\" data-sku=\"R1-10S-MS3\"\u003e\n  \u003csection class=\"crst-hero-summary\"\u003e\n    \u003ch2 class=\"crst-benefit-headline\"\u003e1U Rack Power with Front-Panel Load Telemetry, 10 Individual Switches, and 3900J Surge Defense\u003c\/h2\u003e\n    \u003cp class=\"crst-lead\"\u003eDesigned for homelabs, server closets, and pro AV racks, the R1-10S-MS3 puts a 5-group total-load digital meter and 10 individual switches on the front rack face while keeping all 10 NEMA 5-15R power cords hidden in back—backed by 3900J surge protection.\u003c\/p\u003e\n    \u003cul class=\"crst-core-points\"\u003e\n      \u003cli\u003eFront 5-Group Total-Load Meter: Read live rack watts, volts, amps, power factor ('[' capacitive \/ 'L' inductive), and session\/cumulative kWh \u0026amp; hours—no SNMP or apps.\u003c\/li\u003e\n      \u003cli\u003e10 Front Switches -\u0026gt; 10 Rear Outlets: Conceal all equipment cords inside the cabinet while rebooting individual servers, switches, or amps from the front face.\u003c\/li\u003e\n      \u003cli\u003e3900J 3-Line Surge Protection + Guarded Breaker: Over 2x the surge rating of typical 1800J switched rack strips, paired with a flip-covered 15A master breaker.\u003c\/li\u003e\n      \u003cli\u003eShallow 90 mm 1U Aluminum Build: Spot-welded 3 sq mm copper bus bars inside a 1.5 mm aluminum housing; includes 4 M6 rack screws \u0026amp; 4 cage nuts.\u003c\/li\u003e\n    \u003c\/ul\u003e\n    \u003cdiv class=\"crst-compatibility-callout\"\u003e\n      \u003cp\u003e\u003cstrong\u003eSelection \u0026amp; Compatibility Guide:\u003c\/strong\u003e Built for standard 19-inch 1U racks (4 M6 rack screws and 4 cage nuts included) and vertical under-desk mounting on 15A circuits (125V \/ 15A \/ 1875W max combined load). All 10 AC outlets sit on the rear panel (no front AC socket and no line filter), and the 5-group display reports aggregate 10-outlet rack load. Need 2-stage line noise filtering and a front socket instead of the digital meter? See the R1-11S-F2.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cp class=\"crst-anchor-links\"\u003e\n      \u003ca href=\"\/collections\/metered-filtered-rack-metal-power-strips\"\u003eCompare R1-10S-MS3 vs. R1-11S-F2\u003c\/a\u003e\n    \u003c\/p\u003e\n  \u003c\/section\u003e\n  \u003csection class=\"crst-feature-modules\"\u003e\n    \u003ch2\u003eKey Engineering \u0026amp; Functional Highlights\u003c\/h2\u003e\n    \u003carticle class=\"crst-feature-block\"\u003e\n      \u003ch3\u003eBridge the Gap Between Basic Rack Switchers and High-Cost Enterprise PDUs\u003c\/h3\u003e\n      \u003cp\u003eUntil now, 19-inch rack builders faced a frustrating choice: buy a budget 10-switch strip with zero load visibility and modest surge protection, or spend hundreds on a datacenter metered PDU that omits individual front switches and surge clamping altogether. The CRST R1-10S-MS3 brings live 5-group load monitoring, 10 front switches, and 3900J surge protection together in one 1U chassis.\u003c\/p\u003e\n    \u003c\/article\u003e\n    \u003carticle class=\"crst-feature-block\"\u003e\n      \u003ch3\u003e5-Group Rack Headroom \u0026amp; Venue Voltage Telemetry at Eye Level\u003c\/h3\u003e\n      \u003cp\u003eWhether you are sizing a UPS for a Proxmox homelab cluster or plugging a mobile PA\/DJ rack into an unfamiliar venue outlet, the front digital display immediately shows aggregate active wattage (W), incoming AC voltage (V), current (A), power factor (PF, with '[' indicating capacitive load and 'L' indicating inductive load), plus auto-cycling session and cumulative electricity consumption (up to 19,999 kWh) and runtime hours (up to 19,999 h; timer activates at 5W+).\u003c\/p\u003e\n    \u003c\/article\u003e\n    \u003carticle class=\"crst-feature-block\"\u003e\n      \u003ch3\u003eZero Rear-Cabinet Cable Spaghetti + Instant Front Hard-Reboots\u003c\/h3\u003e\n      \u003cp\u003eAll ten NEMA 5-15R receptacles exit from the rear panel so power bricks and AC cables stay routed inside rear cable managers rather than dangling over front patch panels. Up front, ten softly illuminated manual switches let you power-cycle a locked NAS, PoE switch, or wireless receiver in seconds without disturbing the rest of the stack.\u003c\/p\u003e\n    \u003c\/article\u003e\n    \u003carticle class=\"crst-feature-block\"\u003e\n      \u003ch3\u003e3900J 3-Line Surge Suppression \u0026amp; Flip-Guarded 15A Master Breaker\u003c\/h3\u003e\n      \u003cp\u003eHigh-density rack hardware deserves serious spike protection. The R1-10S-MS3 integrates 3900 Joules (500V VPR) of UL 1449 Type 3 protection across L-N, L-G, and N-G modes with dedicated Grounded and Surge Protected status LEDs, while a hinged clear cover shields the recessed 15A resettable master breaker against accidental bumps.\u003c\/p\u003e\n    \u003c\/article\u003e\n    \u003carticle class=\"crst-feature-block\"\u003e\n      \u003ch3\u003e1.5 mm Extruded Aluminum, Spot-Welded Copper \u0026amp; Included M6 Rack Hardware\u003c\/h3\u003e\n      \u003cp\u003eInside the 90 mm-deep 1U aluminum shell, solid 0.5 x 6 mm (3 sq mm) copper bus bars are spot-welded directly to phosphor bronze contacts for cool, reliable power delivery. Detachable 2 mm steel brackets mount horizontally in standard 19-inch 1U racks using the 4 included M6 rack screws and 4 M6 cage nuts, or rotate vertically for clean under-desk suspension.\u003c\/p\u003e\n    \u003c\/article\u003e\n  \u003c\/section\u003e\n  \u003csection class=\"crst-use-cases\"\u003e\n    \u003ch2\u003eBuilt For Demanding Applications\u003c\/h2\u003e\n    \u003cdiv class=\"crst-use-case-grid\"\u003e\n      \u003cdiv class=\"crst-use-case-card\"\u003e\n        \u003ch3\u003eHomelab, NAS \u0026amp; Proxmox Server Racks\u003c\/h3\u003e\n        \u003cp\u003eTrack exact idle and peak rack wattage from eye level, verify 15A circuit or UPS capacity before adding drives, and hard-reset individual mini-PC nodes from the front panel.\u003c\/p\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"crst-use-case-card\"\u003e\n        \u003ch3\u003eMobile DJ, Live Sound \u0026amp; Stage Flight Cases\u003c\/h3\u003e\n        \u003cp\u003eVerify venue wall voltage immediately upon arrival, keep power draw safely under 15A when lighting and subwoofers kick in, and toggle stage gear cleanly with lighted switches.\u003c\/p\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"crst-use-case-card\"\u003e\n        \u003ch3\u003eIT Network Closets, NVR Security \u0026amp; Smart-Home Racks\u003c\/h3\u003e\n        \u003cp\u003eKeep 10 power cords hidden behind patch panels while giving on-site staff simple, app-free front switches and a flip-guarded master breaker.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n  \u003csection class=\"crst-cross-sell\"\u003e\n    \u003ch2\u003eCompare Related CRST Models\u003c\/h2\u003e\n    \u003cul\u003e\n      \u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"\/products\/crst-r1-11s-f2-1u-filtered-switched-rack-pdu\"\u003eCRST R1-11S-F2\u003c\/a\u003e:\u003c\/strong\u003e Prefer 2-stage audio\/AV line filtering and an 11th front-panel AC socket in 1U (without the digital meter)? Choose the R1-11S-F2.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"\/products\/crst-p2-6s-mf3-2u-filtered-metered-switched-power-strip\"\u003eCRST P2-6S-MF3-2U\u003c\/a\u003e:\u003c\/strong\u003e Want BOTH a digital load meter AND 3-stage filtering plus covered switches in a 2U front-outlet bar? View the P2-6S-MF3-2U.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"\/products\/crst-p2-7sx-ms3-20a-metered-switched-metal-power-strip\"\u003eCRST P2-7SX-MS3\u003c\/a\u003e:\u003c\/strong\u003e Running a dedicated 20-Amp NEMA 5-20R rack or lab circuit? Step up to the 20A 2U P2-7SX-MS3.\u003c\/li\u003e\n    \u003c\/ul\u003e\n    \u003cp\u003e\u003ca href=\"\/collections\/metered-filtered-rack-metal-power-strips\"\u003e\u003cstrong\u003eCompare R1-10S-MS3 vs. R1-11S-F2 →\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n  \u003c\/section\u003e\n\u003c\/div\u003e","brand":"CRST","offers":[{"title":"Default Title","offer_id":63856565977228,"sku":"R1-10S-MS3","price":89.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0365\/1525\/0316\/files\/R1-10S-MS3.jpg?v=1794793535","url":"https:\/\/www.crsttech.com\/products\/crst-r1-10s-ms3-1u-metered-switched-rack-pdu","provider":"CRST","version":"1.0","type":"link"}