CRST 12-Outlet Filtered & Metered 2U Metal Power Strip with 20W USB-C (P2-12-MF3-2U)

Connect up to 12 AC devices and 2 USB devices from a single 2U extruded-aluminum power center. Features two wide-spaced rows of six outlets, a live digital total-load meter, 3-stage EMI/RFI line filtering, 3900J surge protection, and a cover-guarded 15A master breaker.

$99.99
In stock — ships from California within 24h · arrives in 3–7 business days
New-customer offer10% off your first order — unlocks right here

Key Features

  • 12 Front-Accessible Wide-Spaced Outlets
  • 5-Group Total-Load Meter for 12-Plug Setups
  • 3-Stage EMI/RFI Filter + 3900J Surge Protection
  • Master-Controlled 20W USB + Guarded Breaker
See all featuresHide details
  • 12 Front-Accessible Wide-Spaced Outlets

    Dual rows of 6 NEMA 5-15R sockets (~1.7-inch horizontal spacing, outward ground orientation) fit bulky power bricks cleanly.

  • 5-Group Total-Load Meter for 12-Plug Setups

    Prevent overloading your 15A/1875W circuit by watching live watts, volts, amps, power factor ('[' capacitive / 'L' inductive), and session/cumulative kWh & hours.

  • 3-Stage EMI/RFI Filter + 3900J Surge Protection

    Shields multi-device workstations, AV racks, and benches from line interference and 3-line voltage transients.

  • Master-Controlled 20W USB + Guarded Breaker

    Up to 20W single-port USB-C PD (20W shared max across USB-C and USB-A) and all 12 AC sockets controlled together under a flip-covered 15A breaker.

Specifications
Outlets12 AC in 2 rows of 6 (NEMA 5-15R)
Outlet spacing1.7" (horizontal)
USB1 USB-C + 1 USB-A, 20W max (shared), switched by master
SwitchesCovered master switch (all 12 outlets and USB)
Surge protection3900 Joules, 3-line (L-N, L-G, N-G), 500V VPR, with status lights
Electrical rating15A / 125VAC / 60Hz / 1875W
Overload protection15A resettable circuit breaker
Noise filtering3-stage EMI/RFI filter
Cord length6 ft
Cord rating14AWG/3C
PlugNEMA 5-15P, 45° angled flat plug
Housing1.5 mm aluminum alloy, 3 mm² spot-welded copper bus bars, phosphor bronze contacts
MountingDetachable 2 mm steel brackets: 19" rack (2U), wall or bench, or hidden on 16" wall studs (wood screws not included); desk clamp sold separately
Power meterTotal load: watts, volts, amps, power factor, session and cumulative kWh and hours
In the boxPower strip, 2 mounting brackets, 4 M6 rack screws, 4 M6 cage nuts
Dimensions16.54 x 1.77 x 3.54 in
Weight3.25 lb
Insurance$1M product liability coverage
CertificationETL Listed
Warranty18 months, free 36 months with registration
Volume pricingBulk & wholesale
QuantityYou save
5-1010% off
11+15% off

Discount applies automatically in cart and at checkout.

Buying in bulk? Request a quote

Services & Benefits

Free shipping, no minimum
Every order ships free from our California warehouse — no minimum spend. In-stock orders ship within 24 hours on business days, and standard delivery typically runs 3–7 business days.
Safety certified
Independently certified by an OSHA-recognized NRTL (ETL / SGS) — not a self-declared claim. This product’s exact certifying body and the UL standards it’s listed to are shown in the Specifications.
Up to 36-month warranty
18-month warranty as standard, extended to a full 36 months free when you register your strip.
Worry-free ordering
30-day money-back returns — if it’s our defect, return shipping is on us. Backed by $1M product-liability coverage and lifetime technical support.

High-Density 12-Outlet Aluminum Power Hub—With Live Wattage Monitoring and 3-Stage Noise Filtering

Connect up to 12 AC devices and 2 USB devices from a single 2U extruded-aluminum power center. Features two wide-spaced rows of six outlets, a live digital total-load meter, 3-stage EMI/RFI line filtering, 3900J surge protection, and a cover-guarded 15A master breaker.

  • 12 Front-Accessible Wide-Spaced Outlets: Dual rows of 6 NEMA 5-15R sockets (~1.7-inch horizontal spacing, outward ground orientation) fit bulky power bricks cleanly.
  • 5-Group Total-Load Meter for 12-Plug Setups: Prevent overloading your 15A/1875W circuit by watching live watts, volts, amps, power factor ('[' capacitive / 'L' inductive), and session/cumulative kWh & hours.
  • 3-Stage EMI/RFI Filter + 3900J Surge Protection: Shields multi-device workstations, AV racks, and benches from line interference and 3-line voltage transients.
  • Master-Controlled 20W USB + Guarded Breaker: Up to 20W single-port USB-C PD (20W shared max across USB-C and USB-A) and all 12 AC sockets controlled together under a flip-covered 15A breaker.

Selection & Compatibility Guide: All 12 AC outlets and the 20W shared USB-C/USB-A module are controlled together by the recessed, cover-guarded 15A master overload switch (this model does NOT have 12 individual outlet switches) and share a 125V / 15A / 1875W maximum combined rating. Prefer per-outlet manual switches and need fewer sockets? See our 6-Outlet P2-6S-MF3-2U.

Key Engineering & Functional Highlights

Why a 12-Outlet Strip Needs a 5-Group Digital Load Meter Most

The more outlets you have on a single power strip, the easier it is to silently creep past a standard 15A / 1875W circuit rating when towers, monitors, speakers, NAS drives, and chargers wake up at once. The P2-12-MF3-2U takes the guesswork out of high-density wiring with a 5-group digital meter displaying aggregate active power (W), AC voltage (V), current (A), power factor (PF, '[' capacitive / 'L' inductive load), and auto-cycling session and cumulative electricity consumption (up to 19,999 kWh) and runtime hours (up to 19,999 h; timer starts at 5W+).

Adapter-Friendly Dual-Row Geometry—100% Usable on Walls or Racks

Many 12-to-14-outlet rack strips split their sockets between the front and back panels—meaning if you mount the unit flat against a wall or workbench backboard, half the outlets become inaccessible. The P2-12-MF3-2U places all 12 NEMA 5-15R outlets on the front face in two clean rows of six with ~42 mm (1.7 in) horizontal spacing and opposing ground-pin orientation so right-angle plugs and power bricks drape outward without colliding.

3-Stage EMI/RFI Filtering & 3900J 3-Line Surge Suppression

Protect an entire desk or equipment bay with a built-in 3-stage EMI/RFI line filter that attenuates conducted AC noise alongside 3900 Joules (500V VPR) of UL 1449 Type 3 surge protection across L-N, L-G, and N-G modes. Dedicated panel LEDs verify active Grounded and Surge Protected status at a glance.

Clean Master-Switch Architecture + 20W Shared USB-C & USB-A Charging

When 12 devices stay plugged in permanently, a single recessed 15A resettable master breaker beneath a clear protective flip guard keeps wiring clean and prevents accidental foot or elbow shutoffs. Integrated USB-C and USB-A ports deliver up to 20W single-port Power Delivery (20W shared max across both USB ports) and turn off cleanly with the master switch.

1.5 mm Aluminum, Spot-Welded Copper Bus Bars & Included M6 Rack Hardware

Engineered with 0.5 x 6 mm (3 sq mm) solid copper bus bars spot-welded to phosphor bronze contacts inside a 1.5 mm extruded aluminum frame. Reconfigure the 2 mm steel brackets for 19-inch 2U racks (4 M6 rack screws and 4 cage nuts included), exposed bench/garage walls, or hidden 16-inch US wall-stud mounting—or add the optional CRST desk clamp (sold separately).

Built For Demanding Applications

Multi-Monitor Editing, Trading & Engineering Desks

Consolidate computers, triple displays, CalDigit/Thunderbolt docks, desk lamps, speakers, and mobile chargers onto one wall-stud or under-desk power hub—no daisy-chaining required.

AV Media Credenzas, Broadcast Suites & Synth Walls

Power receivers, media servers, game consoles, and outboard gear through 3-stage EMI/RFI filtered sockets with 3900J surge defense and subtle low-glow indicators.

Organized Garage Battery-Charging Walls & Maker Benches

Mount across 16-inch garage studs to feed cordless tool chargers, work lights, routers, and diagnostic tablets while monitoring total circuit amperage.

Compare Related CRST Models

  • CRST P2-6S-MF3-2U: Prefer 6 guarded per-outlet switches over 12 master-controlled outlets (with the exact same 3-stage filter, 3900J, meter, and 20W USB-C)? Choose the P2-6S-MF3-2U.
  • CRST P1-7-MS1: Need a slimmer 1U metered strip for 7 devices without EMI filtering or USB? View the P1-7-MS1.
  • CRST R1-11S-F2: Installing inside a 19-inch rack and want rear-hidden cords with 10 front switches + 1 front outlet + filtering? See the 1U R1-11S-F2.

Compare 12-Outlet vs. 6-Switch Models →

FULL SPECS

Specifications.

Outlets12 AC in 2 rows of 6 (NEMA 5-15R)
Outlet spacing1.7" (horizontal)
USB1 USB-C + 1 USB-A, 20W max (shared), switched by master
SwitchesCovered master switch (all 12 outlets and USB)
Surge protection3900 Joules, 3-line (L-N, L-G, N-G), 500V VPR, with status lights
Electrical rating15A / 125VAC / 60Hz / 1875W
Overload protection15A resettable circuit breaker
Noise filtering3-stage EMI/RFI filter
Cord length6 ft
Cord rating14AWG/3C
PlugNEMA 5-15P, 45° angled flat plug
Housing1.5 mm aluminum alloy, 3 mm² spot-welded copper bus bars, phosphor bronze contacts
MountingDetachable 2 mm steel brackets: 19" rack (2U), wall or bench, or hidden on 16" wall studs (wood screws not included); desk clamp sold separately
Power meterTotal load: watts, volts, amps, power factor, session and cumulative kWh and hours
In the boxPower strip, 2 mounting brackets, 4 M6 rack screws, 4 M6 cage nuts
Dimensions16.54 x 1.77 x 3.54 in
Weight3.25 lb
Insurance$1M product liability coverage
CertificationETL Listed
Warranty18 months, free 36 months with registration

WE CUT BOTH OPEN

Look the same. Not built the same.

Side by side, you can’t tell them apart — same enclosure, same outlet count. The difference is everything inside, so we cut both open.

CRSTBuilt to the standard
CRST exterior
Same footprint, same outlets
CRST one-piece copper bus bars
One-piece copper bus bars
CRST thermal-fused MOV
Thermal-fused MOV, rated joules
CRST clean solder joints
Full, clean solder joints
Typical look-alikeBuilt to a price
Look-alike exterior
Looks identical from the outside
Look-alike copper-clad aluminum
Thin copper-clad aluminum
Look-alike missing surge part
Missing / undersized surge part
Look-alike cold joints
Cold, twisted joints

Both units share the same enclosure and outlet count — the difference is inside. Certified CRST units use one-piece copper bus bars, a thermal-fused MOV, and full solder joints; uncertified look-alikes commonly substitute copper-clad aluminum, omit the thermal fuse, and leave cold joints.

What we cut openCertified CRSTUncertified look-alike
Bus barsOne-piece copper barThin copper-clad aluminum
Surge component (MOV)Thermal-fused, rated joulesMissing or undersized, no thermal fuse
Solder jointsFull, clean jointsCold, twisted joints

CUSTOMER REVIEWS

What buyers say.

PRODUCT FAQ

Common questions.

Does the P2-12-MF3-2U have individual on/off switches for each of the 12 outlets?
No. To accommodate 12 wide-spaced AC outlets, the digital load meter, 3-stage filtering, and USB ports within a compact 16.54-inch 2U footprint, all 12 AC outlets and the USB module are controlled together by the guarded 15A master breaker. If you want individual per-outlet switches in the same 2U filtered series, choose the 6-outlet P2-6S-MF3-2U.
How does the USB charging module allocate power, and is it switched?
USB-C supports up to 20W Power Delivery when used alone, and USB-C + USB-A share 20W maximum combined output when charging two devices together. The USB module is controlled by the main 15A switch.
Can I plug in 12 AC devices and 2 USB devices at the same time?
Yes—as long as the combined draw of all connected equipment stays within the unit's 125V / 15A / 1875W maximum total rating. The 5-group digital meter shows live watts, volts, amps, power factor ('[' capacitive / 'L' inductive), plus session and cumulative kWh and runtime hours up to 19,999 (timer active at 5W+).
Are all 12 outlets accessible if I mount this unit flat against drywall?
Yes! Unlike split front/rear rack PDUs that lose rear outlets when wall-mounted, all 12 AC outlets and both USB ports sit on the front face.
What is the difference between 3-stage EMI/RFI filtering and a UPS?
The 3-stage EMI/RFI filter attenuates high-frequency conducted interference on the AC line and pairs with 3900J surge suppression against voltage spikes. It does not contain a battery for outage backup (UPS) or step voltage up/down (AVR).
Does it fit standard 19-inch racks and 16-inch US wall studs, and are rack screws included?
Yes. Reconfigure the included 2 mm detachable steel mounting ears forward for 19-inch 2U rack rails (4 M6 rack screws and 4 M6 cage nuts are included in the box), rearward-outward for surface mounting, or rearward-inward for concealed 16-inch stud alignment.

Request a bulk quote

Volume discounts apply automatically from 5 units. For larger orders, mixed SKUs, or a PO, send it here.

CRST 12-Outlet Filtered & Metered 2U Metal Power Strip with 20W USB-C (P2-12-MF3-2U) SKU P2-12-MF3-2U

We reply within one business day. Prefer email?info@crsttech.com